The ES200 (non-monitored) and ES2000 (monitored) group of patented Burglar Resistant Strikes are designed for high security applications and manufactured from solid stainless steel.
These strikes have a built in face plate further strengthening the strike to withstand the harshest treatment. They offer a strong dependable and long-lasting electric strike solution and are suitable for use with any access control system using 90 degree swing doors.
These strikes are extremely flexible and can be changed from power-to-lock or power-to-open, mounted on the left or right hand side of the door and come as standard with a continuously rated coil, thus reducing the amount of stock needed to cover each application.

- POWER TO LOCK/POWER TO OPEN Changeable on site
- HIGH SECURITY Tamper resistant to all known techniques
-
4 HOUR FIRE RATING
- INSTALLATION TEMPLATE Easy to use stick-on template for faster installations
- EASIER INSTALLATION Body depth only 27mm
-
CAST STAINLESS STEEL BODY
- EXTRA SECURITY 3 hardened locking pins
- LOW CURRENT Max 175mA at 12 volts DC
- CONTINUOUSLY RATED SOLENOID Solenoid can be continuously powered
- FLEXIBLE CABLE EXIT Interchangeable rear and side
- OPTIONAL MOUNTING KIT Reduces installation time
- Monitored ES2000
- STRIKE MONITORING 3amps changeover contacts
- DOOR AND LATCH MONITORING 3amps changeover contacts

- Electrical Specification 175mA at 12vdc - 88mA at 24vdc (rated for continuous use)
- Door /Latch Monitor - 3amp changeover microswitch
- Holding strength - 1362kg (3000lb)
- Product weight - 487 gms (17.2 oz)
- Shipping weight - 508 gms (17.9 oz)
- Shipping size with box - 195 x 48 x 34 (7 3/4" x 1 15/16" x 1 3/8")

- Approved to Ul1034(highest level)
- Approved to BS5872
- Electromagnetic compatibility - EN500181 - 1 Exempt
Compliant
 The electric strike should be fully monitored using no less than 3 amps contacts and have separatedoor/latch and lock monitor switches. The product should be constructed using solid stainless steel components and provide a minimum 5 years warranty. Where Power to Lock and Power to Open functions may be required in the same building, as ingle electric strike should be interchangeable to either "power to lock" or "power to open" on site.
The electric strike should not consume current greater than 180mA at 12 volt and have a solenoid suitable for continuous use. A maximum projection of 27mm ( 1 1/16 " )for the strike into any door frame is required. A fire rating not less than 4 hours is required where applicable.
|