Trimec ES150 Series Surface Mounted Electric Strike

Trimec ES150 Series Surface Mounted Electric Strike
Trimec ES150 Series Surface Mounted Electric Strike
Trimec ES150 Series Surface Mounted Electric Strike
Trimec ES150 Series Surface Mounted Electric Strike

ES150 is a surface mounted electric strike suitable for use with rim or surface type dead latches. This strike is easy to install and can be simply controlled by a keypad, keyswitch or integrated into any access control system.

ES150 offers high levels of security and features usually provided by more expensive electric locking solutions. The electric strike can be easily installed on steel and wooden door frames. A Weather resistant version is also available for exterior applications.

Key Features

  • Fail safe/fail secure changeable on site
  • Easy installation suitable for steel and wooden door frames
  • Stainless steel striker for extra strength and durability
  • Multi Voltage 12Vdc & 24Vdc
  • Solenoid rated for continuous use
  • IP56 weather resistant version available
  • Australian designed
  • TRICARE® 5 Year Warranty

Applications

  • Surface or rim mounted applications
  • Suitable for use with all access control systems
  • Exposed areas

Standards and Compliance

  • CE Approved
  • C-Tick Certified
  • IP56 Rated
Specification

Voltage
12Vdc & 24Vdc

Current
250mA @12Vdc / 125mA @ 24VDC

Solenoid
Solenoids rated for continuous use.

Monitoring
None

Holding Force
680kg Static Strength Rating

Endurance
Cycle tested to 1,000,000 operations

Environment
Operational temperature range - 20°C to +60°C
Weather resistant construction available (IP56)

Body
Solid Stainless Steel Construction

Keeper
Stainless Steel

Specification Statement
The electric strike must be suitable for surface mount applications for use with rim or surface mount door locks. Where Power To Lock and Power To Open functions may be required in the same building, an individual strike is interchangeable from either "Power to Lock" or "Power to Open" on site.

The electric strike should not consume current greater than 250mA @ 12Vdc / 125mA @ 24Vdc. Certifications must include CE and C-Tick. 

The strike should be tested to 1 million operations and have a minimum holding force not less than 680kg.

Dimensions

Ordering
Ordering Information
Description Part Number
ES151 12/24VDC PTL W/RES 110151-010M
ES152 12/24VDC PTO W/RES 110152-010M

Note: Change from Fail Safe (PTL) to Fail Secure (PTO) as required.